Measure the irradiance intensity on your photovoltaics system precisely at an affordable price with IMT Technology’s robust silicon solar irradiance sensors (Si sensors).
The sensor element’s design is similar to that of a PV module; this means that their spectral response (SR) and incident angle modifier (IAM) are highly comparable. Consequently, these sensors are eminently suitable as a reference for PV system monitoring.
Benefits & Features
- Reference solar cell for PV monitoring
- Calibration measurement uncertainty: 1.2 % (class A as per IEC 61724-1)
- Suitability for outdoor use verified by tests as per IEC 61215
- Extremely few mismatch errors due to optical properties as those of PV modules
- Calibration in relation to spectrum as per IEC 60904-3, AM1.5
- Exceptional linearity significantly above IEC 60904-10 requirements
- Pt1000 as per IEC 60751 Class A to measure cell temperature
- Developed and manufactured in Germany
Digital Si- Sensors (RS485 / MODBUS)
Type | Bild | Measurements | Notes | Bild |
---|---|---|---|---|
Si-RS485TC-T-MB | PV-Referenzzelle Si-RS485TC-T-MB |
1. Solar irradiance 2. Cell temperature | –– | |
Si-RS485TC-2T-MB | PV-Referenzzelle Si-RS485TC-2T-MB |
1. Solar irradiance 2. Cell temperature 3. Ambient temperature |
Firmly connected ambient temperature sensor (3 m connection cable). Optional Shield-Tamb-Si as a weather and radiation protection | |
Si-RS485TC-T-Tm-MB | PV-Referenzzelle Si-RS485TC-T-Tm-MB |
1. Solar irradiance 2. Cell temperature 3. PV module temperature |
Firmly connected module temperature sensor (3 m connection cable) | |
Si-RS485TC-2T-v-MB | PV-Referenzzelle Si-RS485TC-2T-v-MB |
1. Solar irradiance 2. Cell temperature 3. Temperature (PV modul or ambient temperature) 4. Wind speed |
Two waterproof connectors for one temperature sensor and one wind speed sensor. To order separately • External sensors with preconfigurated plug • Optional Shield-Tamb-Si as a weather and radiation protection | |
Si-RS485TC-3T-MB | PV-Referenzzelle Si-RS485TC-3T-MB |
1. Solar irradiance 2. Cell temperature 3. Temperature 1 (PV modul or ambient temperature ) 4. Temperature 2 (PV modul or ambient temperature) |
Two waterproof connectors for two temperature sensor (for example Tmodul-Si and Tamb-Si). To order separately • External sensors with preconfigurated plug • Optional Shield-Tamb-Si as a weather and radiation protection |
Analogue Si- Sensors
Type | Bild | Irradiance at 0 to 1500 W/m² | Temperature at -40 to +90 °C | Bild |
---|---|---|---|---|
Si-V-10TC | 0 to 10 V | – | ||
Si-V-10TC-T | 0 to 10 V | 0 to 10 V | ||
Si-I-420TC | 4 to 20 mA | – | ||
Si-I-420TC-T | 4 to 20 mA | 4 to 20 mA | ||
Si-V-1.5TC | 0 to 1,5 V | – | ||
Si-V-1.5TC-T | 0 to 1,5 V | 0 to 2 V | ||
Si-mV-85 | 0 to approx. 85 mV | – (optional Pt100 / Pt1000) |
PV cell | Monocrystalline silicon; 50 mm x 33 mm, vendor: BigSun, type: B156X1D2A-2010 |
---|---|
Case | Powder-coated aluminium, 155 mm x 85 mm x 39 mm, 350 to 470 g |
Degree of protection | IP 67 |
Operating temperature | -35 to +80°C |
Connection cable | Length: 3 m, PUR sheath, shielded, UV and weather resistant, LiYC11Y, 4 x 0.14 mm² |
Voltage supply | Typical 24 VDC |
Customs tariff number | 90 15 80 20 |
Options for Si- sensors
- DaKKS calibration, DIN EN ISO/IEC 17025
- Customised cable length
- Version with water-proof plug-socket connection
- Si-V-1.5TC also as battery powered version available
- Ready-made multimeter cable for battery
- powered version
- Customised scaling or measuring range
- RS485 versions with MT protocol (ASCII)